Product Information:
This Underfloor Heating Temperature Control Valve is a valve under IFAN, which is mainly used to control the temperature of floor heating, stabilize the constant temperature, and reduce energy consumption.
Product Size:
Size(mm) | PCS/Box | Weight(g) | CBM |
1/2" | 100 | 150 | 0.0272 |
3/4" | 100 | 285 | 0.0272 |

Product Features:
The underfloor heating temperature control series not only includes this Underfloor Heating Temperature Control Valve, but also includes a central control box, a temperature control LCD panel, and an electric heating actuator.
High temperature start mode:
Press the high and low temperature start conversion button by hand. When the mode light on the thermostat panel turns yellow, the thermostat enters the high temperature start mode. When the actual temperature measured by the temperature control probe is higher than the set temperature, the water pump starts to work, and the indicator light is green at this time; when the actual temperature measured by the temperature control probe is lower than the set temperature, the water pump stops working, and the indication is now the light does not show. The high temperature start mode is generally suitable for boiler cycles.

Low temperature start mode:
Press the high and low temperature start conversion button by hand. When the mode light on the thermostat panel turns red, the thermostat enters the high temperature start mode. When the actual temperature measured by the temperature control probe is lower than the set temperature, the water pump starts to work, and the indicator light is green at this time; when the actual temperature measured by the temperature control probe is higher than the set temperature, the water pump stops working, and the indication is now The light does not show. The low temperature start mode is generally suitable for floor heating cycles.
Water shortage protection function:
When there is sewage in the pipeline, regardless of whether the pump is in high temperature start mode or low temperature start mode, the pump is in a power-off state and stops working. At this time, the indicator light flashes green.

Flow adjustment function:
According to the temperature of the primary water supply, manually adjust the opening of the flow valve to meet the mixed water temperature requirements for floor heating.
Remark:
The heating mode refers to adjusting the valve position and the working state of the circulating water pump according to the set temperature value and the detected temperature value;
Debug working mode means to cancel all system protection functions, and the system is forced to run.