Automatic flow regulating valve and automatic pressure regulating valve

Sep 18, 2021

Leave a message

What is an automatic flow regulating valve?

The automatic flow regulating valve relies on the change of the medium parameter itself, which can realize automatic flow adjustment. This refers to a device that includes three functions: measurement, execution, and control. At present, it has been widely used in parameter adjustment and control in heating systems. At present, the automatic flow control valve is basically installed in the plumbing pipe well in the public area. For example, our most common flow meters are basically this kind of automatic flow adjustment control valve.



Precautions for installation of automatic flow regulating valve

The first point is that we must ensure our installation and operation as well as the needs of future operations. Sufficient installation space is required here, and the connecting pipes of the inlet and outlet should be of sufficient length to ensure the performance of the controller.

The second point is that the regulating valve should be installed on the horizontal heating pipe. The controller is required to be on the top and the actuator is on the bottom to ensure that the actuator is in a low temperature position.

The third point is that the installation of the filter in the heating system should be installed in front of the automatic flow control valve. At the same time, pay attention to the direction of installation, and not install it wrong.



What is an automatic pressure regulating valve?

The automatic pressure regulating valve can be divided into the pressure regulating valve before the valve and the pressure regulating valve after the valve. Both of these valves can be used as differential pressure control. The same are all automatic pressure regulating valves. The automatic pressure regulating valve is generally commonly used in our heat exchange station or the heating chamber of the building, or the heating inlet device, and this kind of automatic pressure regulating valve is used. The function is to adjust the pressure of the supply and return water to ensure the pressure difference between the supply and return water and realize the normal circulation of water.



Installation requirements of automatic pressure regulating valve

The first point is that sufficient space for installation and operation is required. Because after the self-operated differential pressure regulating valve is installed, we have to frequently adjust the pressure. Therefore, it is necessary to ensure that there is enough space for installation and operation.

The second requirement is that the connecting pipes on both sides of the inlet and outlet of the regulating valve should maintain a certain straight length. Only in this way can the accuracy of the guaranteed precision be maintained.

The third requirement is that the filter should be set in front of the regulating valve and a bypass valve should be set at the same time.

The fourth requirement is that the regulating valve should be installed on the horizontal pipe for heating, with the controller on the top and the actuator on the bottom. This makes it easy to measure and adjust.