Leave a message


The steel wire braided rubber has high bearing capacity and compression resistance, and the advantage lies in the steel wire reinforcement layer in the pipe, that is to say, the steel wire reinforcement layer belongs to the skeleton of the high-pressure hose. Generally, our common high-pressure hoses are mainly steel wires, which are determined by their bearing capacity. If there is a problem with the reinforcement layer of the high-pressure hose, it can be analyzed and solved according to two points. High pressure hose rupture, causing rust in the wire layer: The cause of the problem is that the grounded cover is corroded by liquids at the production site, or corroded by corrosive substances in the factory. This reduces hose life and ruptures when exposed to high pressure. When the wire braided hose breaks, you may wish to peel off the outer rubber around the rupture of the hose, and observe whether the wire wrapped inside is rusted or corroded. Irregular broken wires in the reinforcement layer in the hose: After the rubber outer layer of the steel wire braided hose is removed, it is found that the reinforcement layer is not rusted, but has irregular broken wires. The main reason for this is that the hose is constantly subjected to high-frequency impact, and the steel wires in the reinforcement layer are crossed. Since these steel wires are woven together, the pressure often changes during use, and the intersection will stagger and generate friction, resulting in the steel wire. fracture.